Electrical Engineer
Location: Doha, Qatar
CURRICULUM VITAE
Name : SHAIK KHALILUDDIN
PERSONAL DETAILS :
Date of Birth : 21-04-1992
Nationality : Indian
Sex : Male
Languages Known : English, Hindi, Telugu, Tamil & Arabic.
Contact Details :- : +918121889387(IND) ; +974 30979644(Qatar)
Skype ID : khaliluddinshaik92
Qatar Driving License.
EDUCATIONAL QUALIFICATION
TECHNICAL : Engineering in Electrical And Electronics with first class in 2015
DESIGNATION : Sr. Electrical Engineer – Testing & Commissioning.
CURRENT EMPLOYER : DIGITAL ENERGY ENGINEERING SERVICES.
PREVIOUS EMPLOYER : VOLTECH ENGINEERING PRIVATE LIMITED.
TOTAL EXPERIENCE : 7+ Years
Job Roles
T&C ACTIVITIES:- Testing and Commissioning Electrical Components like C.Ts, V.Ts, Circuit Breaker, Transformers and Different Relays of Different makes for Different Protections.
CONFIGURATION IN RELAYS:- Configuration of Relays according to the Client’s Requirements.
RED MARKUP:- Updating the Schematics as in Field.
SITE NOTE CLEARENCE:- Clearing the Comments raised by the Consultant with the help of Main Contractor.
RETROFITTING:- Retrofitting of Relays in Control Panels.
TEAM HANDLING:- Handling a team of Engineers and Technicians to finish the Job on time.
SITE CO-ORDINATION:- Cordinating with Managment and Site Incharge to plan for the activity and arranging the Kits and Man Power for that Job.
Technical skill
Preparation and Review of Schematic Drawing, Testing & Commissioning of Components like CT, VT, CB and Transformers.
Testing and Commissioning of Electro-Mech., Static & Numerical relays,
Numerical Relays configuration and testing of
ABB, SIEMENS, AREVA, SCHNEIDER, & ALSTOM
Testing and Commissioning of LCC, Protection Panels.
Modification & configuring Protection schemes as per requirement during Commissioning.
Excellent Presentation and Communication Skills.
KNOWLEDGE IN CONFIGURATION AND TESTING OF NUMERICAL RELAYS
SIEMENS MAKE : 7SA522, 7SA611 – Distance Protection Relay
7SJ61 – Over current & Earth fault Relay
7SJ62, 63, 64 – Multifunction Relays
7UM62- Generator Protection Relay
7UT612, 613 – Differential Relay
7SS52 –Bus bar Relay
6MD85, 7SJ64 – Bay Control Unit Relay
ALSTOM MAKE : P430 – Distance Protection Relay
P543-Line Differential & Distance Relay
P632, P633 – Transformer Protection Relay
P343 – Generator Protection Relay
ABB MAKE : REC 670 & REF 630-Bay Control Unit,
REF 610, 615, 620-FeederRelay
REL 670-Distance protection Relay
RET 670 -Transformer Protection Relay
RED 615-Line Differential Protection Relay
TESTING EQUIPTMENT HANDLED:-
OMICRON – CMC 156,CMC 256, CMC 256-6, CMC 356,
FREJA
MEGGAR
CPC 100
RELAY TOOL HANDLED:-
Micom s1 studio 4.0.1,5.0.1
Alstom Agile 1.2
Digsi 4.82 to 4.89
PCM 600 2.6, 2.8 & 2.9
IT SOFTWARES:-
o MS OFFICE
i) MS WORD-Expert
ii) EXCEL-Competent
iii) POWER POINT-Proficient
o OPERATING SYSTEM
Domestic Experience: 2 Years
SUBSTATION TESTING EXPERIENCE(8 Months)
Commissioning of “400/220KV” Substation at APGENCO, Kalikiri through NR Electric Co. Ltd.
Testing of Electrical equipment like CT, VT, CB, TRANSFORMER and CABLE for 33/11kV, 50MW Solar Power Plant, at Renewable Energy India Ltd., through KEC International.
Testing of Electrical equipment like CT, VT, CB, TRANSFORMER and CABLE for “26MWp” Solar power plant, Veda Solar Power, through L&T Limited, Dindikul, Tamil Nadu, India.
Testing of all Electrical equipment like CT, VT, CB, TRANSFORMER and CABLE for “132/11KV”, 40MW Solar power plant, ACME, through M/s ABB India limited, Chhattisgarh, India.
Testing of “11/6.6KV” Switchgear, at B.P.C.L, through KEPL, Mumbai.
Maintenance of “6MW” Sun Clean Solution, through L&T Limited, Gujarat Solar Park, Charanka, India.
RELAY TESTING EXPERIENCE
Configuration and testing of SIEMENS & ABB make Distance protection, Transformer Protection, breaker Failure Protection, Bus bar Protection and Feeder Management Relays at 400/220 kv Switchyard (PGCIL), Muktsar, Punjab Through M/s SIEMENS Ltd.
The following relays are tested at the above assignment
7UT 613 -Transformer Protection Relay
REL 670 – Distance Protection Relay
7SJ 601-Feeder Protection Relay
6MD66-Bay Control Unit Relay
Configuration and testing of AREVA &SIEMENS & ABB make Transformer protection, Feeder Protection relays(RED 615,REF 615, REF 630, 7SJ622, 7SJ804, P143, P632) at 66/11kv substation (IOCL), Paradip, Orissa through M/s Rohini Industrial Electricals Ltd.
Configuration and testing of SIEMENS make Distance protection, Transformer Protection, Breaker Failure Protection & Feeder Protection relays (7SA522, 7UT613, 7SJ804) at 220/132/33 kv Switchyard (WBSTCL), Purulia, West Bengal, through M/s SIEMENS Ltd.
Configuration and testing of AREVA make Generator protection relay (P343) at 5.7MW Power Plant (INTERNATIONAL PAPER APPM LTD), Rajahmundry, Andhra Pradesh, through M/s TDPS Ltd.
Configuration and testing of SIEMENS make Transformer Protection, Breaker Failure Protection, Feeder Protection & Bus bar Protection relays ( 7UT613, 7SJ804, 7SS52) at 220/132/33 kv Switchyard (WBSTCL), Foundry Park, West Bengal, through M/s SIEMENS Ltd.
Configuration and testing of AREVA make Feeder Protection relays (P141) at (VIZAG STEEL PLANT), Visakhapatnam, A.P through M/s ATLAS COPCO INDIA Ltd.
Configuration and testing of SIEMENS make Transformer Protection, Cable Differential Protection & Feeder Protection relays (7UT613, 7SJ804, 7SD610) at 220/132/33/6.6 kv GIS (TATA STEEL LTD), Kalinganager, Jajpur K Road(Odisha) through M/s SIEMENS Ltd.
Scheme Checking for 220/132 kv Relay Protection Panels for TNEB and APTRANSCO through NR Solutions, Maharastra.
Retrofitting and Commissioing of P143 relay instead of P127 realay for 11kv at SEMBCORB, Nellore.
Scheme Checking for 220/132 kv LCC Panels for PGCL and KTPCL through ABB Factory, Bangalore.
Relay Testing of RET 650, RET 670, REB 670, REL 670, and GE Relays P141 as well as
Configuring and establishing Communication Ethernet Switch for various projects at ABB Factory, Peenya, Bangalore.
International Experience: 4+ Years
Maintenanace of 22/11kV Substation for ABB CIRCUIT BREAKERS and PROTECTION RELAYS at QATAR PORTS MANAGEMENT COMPANY, MESAIED PORT on behalf of SIEMENS CONSORTIUM, Qatar.
TESTING & COMMISSIONING OF 22/0.415kV Substation for ABB C&R PANELS and RELAYS – REF620, RET615, RED615, REF615, Line DIfferential, Trasnformer Differential, Feeder Protection and Bay Control Unit at QATAR EMIRI NAVAL FORCES, NEW PORT on behalf of HITACHI ENERGY, Qatar.
Maintenanace of 22/11kV Substation for SCHNEIDER PROTECTION RELAYS SEPAM RELAYS using SFT2841 at QATAR PETROLEUM, on behalf of SCHNEIDER, Qatar.
Simulating SCS signals at 132/11Kv UmmGarn Substation, for Kahramaa on behalf of SIEMENS CONSORTIUM, Qatar.
Testing of Siemens 6MD85 BCU and 7SJ61 O.C & E.F relays for Over Current, Earth Fault, Thermal, SOTF and Harmonics Protections at 132/11/66Kv UmmEbariya Substation, for Kahramaa on behalf of SIEMENS CONSORTIUM, Qatar.
Testing of Siemens 6MD85 BCU and 7SJ64 Dir.O.C relays for Directional Over Current, at 66/11Kv Abu Hamour West Substation, for Kahramaa on behalf of SIEMENS CONSORTIUM, Qatar.
Testing of ABB REF615 relays for Over Current, Earth Fault, Thermal, SOTF and Harmonics Protections at 132/11KV RAF-3 Substation for Kahramaa on behalf of L&T PT&D, Qatar.
Testing of Backup O.C & E.F relays at 132/11KV Manateq-1 Substation for Kahramaa on behalf of L&T PT&D, Qatar.
Component Testing of ABB REF615 relays for O.C & E.F at 132/11KV Al-Froosh Substation for Kahramaa on behalf of ABB Qatar.
Testing of Siemens 6MD85 BCU and final setting for BACK UP RELAYS like 7SJ81 relays for Over Current protection, at 132/33/11kV Ain Hamad Substation, for Kahramaa on behalf of NCC, Qatar.
Component Testing of 7SJ64 relays for Directional Over Current, at 132/33Kv New Asri, for Kahramaa on behalf of SIEMENS CONSORTIUM, Qatar.
Indulged in KAHRAMAA WITNESS for 132/33kV Protection Relays Trip Test for UMM GARN Substation along with the Cordination of SIEMENS CONSORTIUM.
Indulged in KAHRAMAA WITNESS for 132/33/11kV Protection Relays Trip Test for Ain Hamad Substation along with the Cordination of SIEMENS CONSORTIUM.
International Experience Approvals:
eDF :
LAHMEYAR INTERNATIONAL :
(i). BACK UP RELAYS COMPONENT TESTING
(i). BCU COMPONENT TESTING,
(ii). BACK UP RELAYS COMPONENT TESTING
(iii).U/V RELAYS TESTING, ,
(iv) AC/DC CHECKS,
(v). BI CHECKS,
(vi). METER CALIBRATION.
EPE : (i). BCU COMPONENT TESTING
(ii). BACK UP RELAYS COMPONENT TESTING
(iii). AUXILIARY RELAY TESTING,
(iv). AC/DC CHECKS.
DECLARATION :
I here by declare that all the information stated above is true to best of my knowledge and belief.
Thanks & regards,
SK.KHALILUDDIN
Education
- 2015
Engineering in Electrical and Electronics Engineering at Jawaharlal Nehru Technological University
Experience
- 2015/2012
Electrical Protection Engineer at Voltech Engineering Private Limited
- 2021
Senior Electrical Engineer at Digital Energy Engineering Services
Only Employers can view Contact Details. Request Access